Creating the aF4 Schedule in Hydros™Updated 6 months ago
Add a new schedule:
Type: Flow Pattern
Pattern: Constant Speed
Constant Speed: 100%
Reverse: Off
Pump Count: 1
Pump 1: THIS IS THE OUTPUT YOU MADE IN SECTION 3
Schedule
Enable Advanced Settings: NO
Start Time: (Desired Feed Time)
Run Time: (1:00 to 5:00 minutes, anything over 10 seconds triggers the aF4)
Control Input (Advanced): 0-10v Input 1 (Blk)
Advanced Settings would allow for multiple feeds per day and skipping days. User experimentation required to achieve desired results with those settings.